Commission Delegated Regulation (EU) No 65/2014 of 1 October 2013 supplementing D... (32014R0065)
Commission Delegated Regulation (EU) No 65/2014 of 1 October 2013 supplementing D... (32014R0065)
COMMISSION DELEGATED REGULATION (EU) No 65/2014
of 1 October 2013
supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of domestic ovens and range hoods
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Responsibilities of suppliers and timetable
Article 4
Responsibilities of dealers
Article 5
Measurement and calculation methods
Article 6
Verification procedure for market surveillance purposes
Article 7
Review
Article 8
Repeal
Article 9
Transitional provisions
Article 10
Entry into force and application
ANNEX I
Efficiency classes
1. DOMESTIC OVENS
|
Energy Efficiency Class |
Energy Efficiency Index (EEIcavity) |
|
A+++ (most efficient) |
EEIcavity < 45 |
|
A++ |
45 ≤ EEIcavity < 62 |
|
A+ |
62 ≤ EEIcavity < 82 |
|
A |
82 ≤ EEIcavity < 107 |
|
B |
107 ≤ EEIcavity < 132 |
|
C |
132 ≤ EEIcavity < 159 |
|
D (least efficient) |
EEIcavity ≥ 159 |
2. DOMESTIC RANGE HOODS
|
Energy Efficiency Class |
Energy Efficiency Index (EEIhood) |
|||
|
Label 1 |
Label 2 |
Label 3 |
Label 4 |
|
|
A+++ (most efficient) |
|
|
|
EEIhood < 30 |
|
A++ |
|
|
EEIhood < 37 |
30 ≤ EEIhood < 37 |
|
A+ |
|
EEIhood < 45 |
37 ≤ EEIhood < 45 |
37 ≤ EEIhood < 45 |
|
A |
EEIhood < 55 |
45 ≤ EEIhood < 55 |
45 ≤ EEIhood < 55 |
45 ≤ EEIhood < 55 |
|
B |
55 ≤ EEIhood < 70 |
55 ≤ EEIhood < 70 |
55 ≤ EEIhood < 70 |
55 ≤ EEIhood < 70 |
|
C |
70 ≤ EEIhood < 85 |
70 ≤ EEIhood < 85 |
70 ≤ EEIhood < 85 |
70 ≤ EEIhood < 85 |
|
D |
85 ≤ EEIhood < 100 |
85 ≤ EEIhood < 100 |
85 ≤ EEIhood < 100 |
EEIhood ≥ 85 |
|
E |
100 ≤ EEIhood < 110 |
100 ≤ EEIhood < 110 |
EEIhood ≥ 100 |
|
|
F |
110 ≤ EEIhood < 120 |
EEIhood ≥ 110 |
|
|
|
G (least efficient) |
EEIhood ≥ 120 |
|
|
|
|
Fluid Dynamic Efficiency Class |
Fluid Dynamic Efficiency (FDEhood) |
|
A (most efficient) |
FDEhood > 28 |
|
B |
23 < FDEhood ≤ 28 |
|
C |
18 < FDEhood ≤ 23 |
|
D |
13 < FDEhood ≤ 18 |
|
E |
8 < FDEhood ≤ 13 |
|
F |
4 < FDEhood ≤ 8 |
|
G (least efficient) |
FDEhood ≤ 4 |
|
Lighting Efficiency Class |
Lighting Efficiency (LEhood) |
|
A (most efficient) |
LEhood > 28 |
|
B |
20 < LEhood ≤ 28 |
|
C |
16 < LEhood ≤ 20 |
|
D |
12 < LEhood ≤ 16 |
|
E |
8 < LEhood ≤ 12 |
|
F |
4 < LEhood ≤ 8 |
|
G (least efficient) |
LEhood ≤ 4 |
|
Grease Filtering Efficiency Class |
Grease Filtering Efficiency (%) |
|
A (most efficient) |
GFEhood > 95 |
|
B |
85 < GFEhood ≤ 95 |
|
C |
75 < GFEhood ≤ 85 |
|
D |
65 < GFEhood ≤ 75 |
|
E |
55 < GFEhood ≤ 65 |
|
F |
45 < GFEhood ≤ 55 |
|
G (least efficient) |
GFEhood ≤ 45 |
ANNEX II
Measurements and calculations
1. DOMESTIC OVENS
2. DOMESTIC RANGE HOODS
2.1.
Calculation of the Energy Efficiency Index (EEI
hood
)
2.2.
Calculation of the Fluid Dynamic Efficiency (FDE
hood
)
2.3.
Calculation of the Lighting Efficiency (LE
hood
)
2.4.
Calculation of the Grease Filtering Efficiency (GFE
hood
)
2.5.
Noise
ANNEX III
The label
1. LABEL FOR DOMESTIC OVENS
1.1.
Domestic electric ovens
1.1.1.
Label presentation — for each cavity of a domestic electric oven
1.1.2.
Label information — domestic electric ovens
1.1.3.
Label design — domestic electric ovens
1.2.
Domestic gas ovens
1.2.1.
Label presentation — for each cavity of a domestic gas oven
1.2.2.
Label information
1.2.3.
Label design — domestic gas ovens
2. LABEL FOR DOMESTIC RANGE HOODS
2.1.
Label formats
2.1.1.
Domestic range hoods in energy efficiency classes A to G (label 1)
2.1.2.
Domestic range hoods in energy efficiency classes A+ to F (label 2)
2.1.3.
Domestic range hoods in energy efficiency classes A++ to E (label 3)
2.1.4.
Domestic range hoods in energy efficiency classes A+++ to D (label 4)
2.2.
Label information — domestic range hoods
2.3.
Label design — domestic range hoods
ANNEX IV
Fiche
A. FICHE FOR DOMESTIC OVENS
B. FICHE FOR DOMESTIC RANGE HOODS
ANNEX V
Technical documentation
A. TECHNICAL DOCUMENTATION FOR DOMESTIC OVENS
B. TECHNICAL DOCUMENTATION FOR DOMESTIC RANGE HOODS
ANNEX VI
Information to be provided in the cases where end-users cannot be expected to see the product displayed, except on the internet
A. DOMESTIC OVENS
B. DOMESTIC RANGE HOODS
ANNEX VII
Information to be provided in the case of sale, hire or hire-purchase through the internet
|
|
|
ANNEX VIII
Procedure for product conformity checking by market surveillance authorities
|
Measured parameters |
Verification tolerances |
|
Mass of the oven (M) |
The determined value shall not exceed the declared value of M by more than 5 %. |
|
Volume of the cavity of the oven (V) |
The determined value shall not be lower than the declared value of V by more than 5 %. |
|
ECelectric cavity, ECgas cavity |
The determined value shall not exceed the declared value of ECelectric cavity, ECgas cavity by more than 5 %. |
|
WBEP, WL |
The determined value shall not exceed the declared value of WBEP, WL by more than 5 %. |
|
QBEP, PBEP |
The determined value shall not be lower than the declared value of QBEP, PBEP by more than 5 %. |
|
Qmax |
The determined value shall not exceed the declared value of Qmax by more than 8 %. |
|
Emiddle |
The determined value shall not be lower than the declared value of Emiddle by more than 5 %. |
|
GFEhood |
The determined value shall not be lower than the declared value of GFEhood by more than 5 %. |
|
Po, Ps |
The determined value of power consumption Po and Ps shall not exceed the declared value by more than 10 %. The determined value of power consumption Po and Ps of less than or equal to 1,00 W shall not exceed the declared value by more than 0,10 W. |
|
Sound power level LWA |
The determined value shall not exceed the declared value. |