Commission Delegated Regulation (EU) No 1254/2014 of 11 July 2014 supplementing D... (32014R1254)
Commission Delegated Regulation (EU) No 1254/2014 of 11 July 2014 supplementing D... (32014R1254)
COMMISSION DELEGATED REGULATION (EU) No 1254/2014
of 11 July 2014
supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of residential ventilation units
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Responsibilities of suppliers
Article 4
Responsibilities of dealers
Article 5
Measurement methods
Article 6
Verification procedure for market surveillance purposes
Article 7
Review
Article 8
Entry into force
ANNEX I
Definitions applicable for Annexes II to IX
ANNEX II
Specific energy consumption classes
|
SEC class |
SEC in kWh/a.m2 |
|
A+ (most efficient) |
SEC < – 42 |
|
A |
– 42 ≤ SEC < – 34 |
|
B |
– 34 ≤ SEC < – 26 |
|
C |
– 26 ≤ SEC < – 23 |
|
D |
– 23 ≤ SEC < – 20 |
|
E |
– 20 ≤ SEC < – 10 |
|
F |
– 10 ≤ SEC < 0 |
|
G (least efficient) |
0 ≤ SEC |
ANNEX III
The label
ANNEX IV
Product fiche
ANNEX V
Technical documentation
ANNEX VI
Information to be provided where end-users cannot be expected to see the product displayed, except on the internet
ANNEX VII
Information to be provided in the case of sale, hire or hire-purchase through the internet
ANNEX VIII
Measurements and calculations
|
general typology |
MISC |
||||
|
Ducted ventilation units |
1,1 |
||||
|
Non-ducted ventilation units |
1,21 |
||||
|
ventilation control |
CTRL |
||||
|
Manual control (no DCV) |
1 |
||||
|
Clock control (no DCV) |
0,95 |
||||
|
Central demand control |
0,85 |
||||
|
Local demand control |
0,65 |
||||
|
motor & drive |
x-value |
||||
|
on/off & single speed |
1 |
||||
|
2-speed |
1,2 |
||||
|
3-speed |
1,5 |
||||
|
variable speed |
2 |
||||
|
Climate |
th in h |
ΔΤh in K |
tdefr in h |
ΔΤdefr in K |
Qdefr (*1) in kWh/a.m2 |
|
Cold |
6 552 |
14,5 |
1 003 |
5,2 |
5,82 |
|
Average |
5 112 |
9,5 |
168 |
2,4 |
0,45 |
|
Warm |
4 392 |
5 |
— |
— |
— |
|
Defaults |
value |
||||
|
specific heat capacity of air, cair in kWh/(m3K) |
0,000344 |
||||
|
net ventilation requirement per m2 heated floor area, qnet in m3/h.m2 |
1,3 |
||||
|
reference natural ventilation rate per m2 heated floor area, qref in m3/h.m2 |
2,2 |
||||
|
annual operating hours, ta in h |
8 760 |
||||
|
primary energy factor electric power generation & distribution, pef |
2,5 |
||||
|
space heating efficiency, ηh |
75 % |
||||
ANNEX IX
Verification procedure for market surveillance purposes
|
Parameter |
Verification tolerances |
|
SPI |
The measured value shall be no more than 1,07 times the maximum declared value. |
|
Thermal efficiency RVU |
The measured value shall be no less than 0,93 times the minimum declared value. |
|
Sound power level |
The measured value shall be no more than the maximum declared value plus 2 dB. |